Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200801405 - Employee's Fingers Are Amputated in Unguarded Press Brake

Accident Summary Nr: 200801405 -- Report ID: 0523300 -- Event Date: 06/24/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30838102907/05/20052452321992Wick Building Systems Inc

Abstract: At approximately 10:15 a.m. on June 24, 2005, an employee was bending a piece of metal building trim that was L shaped. One leg of the part measured 2-in. and the other leg measured 1.5-in. Two of the employee's fingers were amputated in a Pacific press brake. There was no guarding on the press brake, and the employee was using a foot treadle to operate the machine. In addition, the employee was not using a two-step method for bending the parts.

Keywords: FRACTURE, AMPUTATED, PRESS BRAKE, FINGER, CAUGHT BETWEEN, UNGUARDED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308381029 Non Hospitalized injury Fracture Fabricating machine operators, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.