Accident: 200800803 - Six Employees Overexposed To Carbon Monoxide From Fork Lifts

Accident: 200800803 -- Report ID: 0523300 -- Event Date: 12/27/2002
InspectionOpen DateSICEstablishment Name
30610470402/10/20035084Wisconsin Lift Truck Corp.

On December 27, 2002, six employees were overexposed to carbon monoxide due to LP fork lifts operating without adequate ventilation within the warehouse and enclosed trailers. The calculated carbon monoxide exposure was 230 ppm as a time-weighted average. Five employees were treated and released from the hospital and Employee #1 was admitted overnight. Employees experienced headaches, dizziness and red faces.

Keywords: asphyxiated, ventilation, warehouse, headache, industrial truck, dizziness, trailer, carbon monoxide

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 306104704 Hospitalized injury Asphyxia Truck drivers, light

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.