Accident Summary Nr: 200782720 - Employee killed when truck overturned

Accident Summary Nr: 200782720 -- Report ID: 0626300 -- Event Date: 04/17/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30546548604/17/20031711238210C & H Power Line

Abstract: On April 17, 2003, Employee #1 was working from an aerial lift bucket, 30 ft high. The entire boom and truck fell over, and Employee #1 was killed.

Keywords: BOOM, TRUCK, FALL, AERIAL LIFT, OVERTURN
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerline, transmission line New project or new addition $500,000 to $1,000,000 30 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 305465486 Fatality Bruise/Contus/Abras Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 30 feet
Cause: Fencing, installing lights, signs, etc.
Fatality Cause: Fall from/with platform catwalk (attached to struc

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.