Accident Summary Nr: 200774214 - Employee Is Injured in Fall from Ladder

Accident Summary Nr: 200774214 -- Report ID: 0134000 -- Event Date: 09/19/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30931023309/19/20057349561720One Source Facility Services, Inc.

Abstract: On September 19, 2005, Employee #1 was carrying equipment and descending a metal window washer's ladder from one roof to another. The ladder end slipped on the wet smooth surfaced roof due to the rounded rail ends. Employee #1 fell and sustained bruises, contusions, and abrasions. He was not hospitalized. The ladder did not have slip-resistant feet.

Keywords: ROOF, RAIL, LADDER, SLIP, DESCENDING, ABRASION, FALL, CONTUSION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309310233 Non Hospitalized injury Bruise/Contus/Abras Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.