Accident Summary Nr: 200772192 - Ironworker Injured in Fall from Beam

Accident Summary Nr: 200772192 -- Report ID: 0134000 -- Event Date: 08/15/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30382416308/15/200217910Builders Resource Corp.

Abstract: On August 15, 2002, Employee #1, an ironworker, was using a lanyard with a large 2.25 in. rebar hook connected to a beam walker, when he fell, sustaining a dislocation injury, for which he was hospitalized. The manufacturer stated that the components were incompatible due to the size of the gate on the lanyard which is only required to take a 220 lb side load by the ANSI standards. The manufacturer also stated that employers are required to ensure that fall protection components are compatible. Employee #1 was hospitalized.

Keywords: ATTACHMENT HOOK, REBAR, IRON WORKER, WORK RULES, CONSTRUCTION, DISLOCATED, LANYARD, FALL, FALL PROTECTION, WALKING ON BEAM
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building New project or new addition $5,000,000 to $20,000,000 4 48

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303824163 Hospitalized injury Dislocation Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 16 feet
Cause: Erecting structural steel
Fatality Cause: Fall, other

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.