Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200771780 - Employee injured in fall from boom following electric shock

Accident Summary Nr: 200771780 -- Report ID: 0134000 -- Event Date: 03/05/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30381063403/06/200217940Northwest Excavating Inc.

Abstract: On March 5, 2002, Employee #1, of Northwest Excavating, Inc., climbed up onto the boom of a Cat excavator EX-6 to mark overhead lines with warning tape. In the process, he contacted the 13.8-kilovolt power line. He received an electric shock that caused him to fall off the boom. He dropped approximately 16 ft and landed, face first, onto large gravel. Employee #1 sustained multiple injuries, for which he was hospitalized.

Keywords: OVERHEAD POWER LINE, WORK RULES, STRUCK AGAINST, CONSTRUCTION, EARTHMOVING EQUIP, ELECTRIC SHOCK, EXCAVATOR, FALL
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition $1,000,000 to $5,000,000 2 28

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 303810634 Hospitalized injury Electric Shock Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Excavation
Fatality Cause: Electrocution by touching exposed wire/source

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.