Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200757474 - Employee Is Crushed and Killed When Pinned Between Two Tanks

Accident Summary Nr: 200757474 -- Report ID: 0522500 -- Event Date: 03/05/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30654497403/05/20043272327390Ec Babbert, Inc.

Abstract: On March 5, 2004, an employee was pinned between a 7,500 lbs septic tank on a forklift and a 7,500 lbs septic tank in storage. The employee drove up close to the other tank to offload it, dismounted the forklift while it was running and the loaded 6 to 7 inches off the ground, to place 4 by 4's under each side of the tank. Employee was found pinned between the two tanks. There were no witnesses to the accident. Investigation revealed that the operator did not lower the forks prior to dismounting the lift.

Keywords: CHEST, ASPHYXIATED, PINNED, STORAGE TANK, CAUGHT BETWEEN, CRUSHED, INDUSTRIAL TRUCK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306544974 Fatality Asphyxia Industrial truck and tractor equipment operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.