Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200740413 - Employee Killed When Run Over By Tractor

Accident: 200740413 -- Report ID: 0213100 -- Event Date: 04/27/1999
InspectionOpen DateSICEstablishment Name
30254938104/27/19991761Latham Village Associates Dba Latham Village Apts.

At approximately 10:30 a.m. on April 27, Employee #1 and a coworker were cleaning up debris from a recently completed roofing job. Employee #1 had just driven a Ford D4040 tractor to bring a bucket load of debris to the dumpster. When he returned, he stepped down from the seat and held a very brief conversation with his coworker in which they decided to move the tractor closer to the building. As they were talking, the tractor began to roll backward. Employee #1, who was still standing next to it, apparently reached toward the controls and pushed the gear shift lever. The tractor lurched forward, struck his leg, knocked him to the ground, then ran over him. The coworker was unable to help Employee #1 without endangering himself, except to get medical aid. Employee #1 was pronounced dead at the scene.

Keywords: vehicle in gear, brake, work rules, cleaning, construction, crushed, struck by, tractor, run over, motor vehicle
Accident Details
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Multi-family dwelling Maintenance or repair $50,000 to $250,000 2 X

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation Construction
1 302549381 Fatality Other Construction trades, n.e.c. FallDist:
FallHt:
Cause: Roofing
FatCause: Crushed/run-over by construction equipment during

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.