Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200712685 - Employee Is Killed When Struck by Pipe Wrench

Accident Summary Nr: 200712685 -- Report ID: 0636900 -- Event Date: 10/14/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30864895510/14/20051381213111Felderhoff Brothers Drilling

Abstract: On October 14, 2005, Employee #1 was assisting in servicing a duplex mud pump. He was struck by a 36-in. pipe wrench, situated on the rotating shaft of the diesel engine, when the clutch was engaged. Employee #1 was killed. At the time of the accident, the engine was running.

Keywords: MAINTENANCE, MUD PUMP, ROTATING SHAFT, CLUTCH, PIPE WRENCH, CONSTRUCTION, ENGINE, LOCKOUT, STRUCK BY, HAND TOOL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308648955 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.