Return to Accident Search Results
Accident Report Detail
Accident Summary Nr: 200712016 - Employee is killed in explosion
Accident Summary Nr: 200712016 -- Report ID: 0636900 -- Event Date: 08/14/2003
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
| 306202417 | 08/14/2003 | 1799 | 238990 | Industrial Prime Contractors |
Abstract:
On August 14, 2003, Employee #1 was replacing a 3-in. pipe/nozzle which had previously ruptured in a pressure vessel used to extract carbon dioxide from natural gas. The valves were closed, the vessel was ventilated with a small fan, the manways were open at the top and bottom, and a Scott Scout monitor was used to measure for oxygen and combustible gas. After removing the nozzle, he was dressing up the hole by arc gouging and grinding, and then paused to check the progress of the work. A few minutes later, an explosion occurred and Employee #1 was killed.
Keywords:
GRINDER, OXYGEN, FAN, VENTILATION, PRESSURE VESSEL, NATURAL GAS, EXPLOSION, VALVE, CARBON DIOXIDE, PIPE
Accident Details
| End Use |
Project Type |
Project Cost |
Stories |
Non-building Height |
Fatality |
| Tower, tank, storage elevator |
Maintenance or repair |
Under $50,000 |
|
60 |
X |
Employee Details
| Employee # |
Inspection Nr |
Age |
Sex |
Degree of Injury |
Nature of Injury |
Occupation |
| 1 |
306202417 |
|
|
Fatality |
Other |
Welders and cutters |