Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200711919 - Employee Killed When Struck By Tongs

Accident Summary Nr: 200711919 -- Report ID: 0636900 -- Event Date: 04/13/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
11003939304/16/20011381213111Patterson Drilling Company Lp

Abstract: Employee #1 and other employees were tripping out pipe on a rotary drilling rig. They were using breakout tongs and rotary power for the initial breakout of the tool joints. The crew had pulled out about eight stands of pipe using this method. During the next work cycle, a bolt securing the tong line pin to the lever broke. The snub line, connected to the end of the tongs, fell free allowing the tongs to spin with the pipe. The rotating tongs struck Employee #1, killing him.

Keywords: PIN, BOLT, DRILL RIG--NON-OIL, PIPE, STRUCK BY, TONGS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 110039393 Fatality Fracture Drillers, oil well

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.