Accident Summary Nr: 200710648 - Employee killed when crushed by rolling tank

Accident Summary Nr: 200710648 -- Report ID: 0636900 -- Event Date: 02/26/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30052121803/01/199937430Trinity Industries, Inc. - Plant 22

Abstract: Employee #1 was on the workroom floor when a coworker was using an overhead crane to lift a railroad tank. As the tank was being raised, it bumped against a smaller tank sitting on the workroom floor, between 7 and 10 in. from the north end of the tank being lifted. The bump caused the smaller tank to roll toward Employee #1, who was crushed against a work platform. He died of head injuries sustained in the accident.

Keywords: CLEARANCE, HOISTING MECHANISM, UNSECURED, WORK RULES, STRUCK AGAINST, CAUGHT BETWEEN, CRUSHED, STRUCK BY, TANK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 300521218 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.