Accident Report Detail
Accident Summary Nr: 200690295 - Three employees killed, eight injured in explosion
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 300506060 | 02/25/1999 | 3321 | 0 | Jahn Foundry Corp. |
Abstract: Employees #1 through #12 were in the shell mold department when there was a large explosion. All twelve sustained burns, from which Employees #6, #8, and #12 died. Employees #1 through #5, #7, and #9 through #11 were hospitalized.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 2 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 3 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 4 | 300506060 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 5 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 6 | 300506060 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 7 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 8 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 9 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 10 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported | ||
| 11 | 300506060 | Fatality | Burn/Scald(Heat) | Occupation not reported | ||
| 12 | 300506060 | Hospitalized injury | Burn/Scald(Heat) | Occupation not reported |