Accident Summary Nr: 200677276 - Employee Is Killed in Fall from Decking on Roof

Accident Summary Nr: 200677276 -- Report ID: 0418800 -- Event Date: 04/08/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31109089804/08/20081791238120Marrow Steel Erectors, Inc.

Abstract: On April 8, 2008, an employee was repositioning a section of metal decking on the roof of a building, when he fell through an opening approximately 3 feet by 5 feet wide, falling approximately 42 feet to the ground and died as a result of the injuries sustained from the fall. The employee was an apprentice iron worker and was not wearing his body harness, nor was there an anchor point to tie of to. The decking had been placed inverted on the roof to allow for more concrete to be poured so that the roof of the building would be able to handle the vibrations of the bio-waste processing plant. The section of decking where the employee fell was removed so that the joists could be inspected. The employee had been told that morning to put his safety harness on by his foreman. The crew went on break at approximately 9:30 a.m. and returned to work shortly thereafter. The foreman did not check on the employees to ensure that they were wearing their safety harnesses, nor did he inspect the roof area to ensure the cable line that was used as the tie off point was still in tact. The employees had removed the cable line which ran across that section of decking and did not have another anchor point to tie of too. The company had trained employees on fall protection and did provide them with body harnesses. Additionally, employees had been instructed on the proper use and wear of the body harnesses, and the proper points to tie off too. The company did have a written safety and health program and holds weekly safety meetings on site.

Keywords: FRACTURE, HEAD, ROOF, INEXPERIENCE, METAL DECKING, FALL, FALL PROTECTION, WORK SURFACE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $1,000,000 to $5,000,000 1 50 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 311090898 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: 50 feet
Cause: Erecting structural steel
Fatality Cause: Fall from roof

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.