Accident Summary Nr: 200671402 - electric shock - contact with overhead line thru load line

Accident Summary Nr: 200671402 -- Report ID: 0418800 -- Event Date: 09/17/1998
Inspection NrDate OpenedSICNAICSEstablishment Name
30049980309/18/199816290Marco Marine Construction, Inc.

Abstract: An employee was on the bed of a flatbed trailer, helping to guide a concrete piling being lifted by a Bucyrus Erie Model 30B friction crawler crane. The load line contacted a 14.4-kilovolt overhead power line. The employee, who was touching the chain sling holding the piling, was electrocuted. (He was pronounced dead at the hospital.)

Keywords: OVERHEAD POWER LINE, ELECTRICAL, ELECTROCUTED, E C, LOAD LINE, CRANE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Single family or duplex dwelling New project or new addition Under $50,000 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300499803 Fatality Electric Shock Construction laborers Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Bituminous concrete placement
Fatality Cause: Electrocution by equipment contacting wire

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.