Accident Summary Nr: 200670776 - Employee dies of carbon monoxide poisoning

Accident Summary Nr: 200670776 -- Report ID: 0418800 -- Event Date: 06/20/1997
Inspection NrDate OpenedSICNAICSEstablishment Name
30049437406/23/199717710Concrete Cutting And Breaking Inc

Abstract: Employee #1 was operating a gasoline-powered concrete saw in an enclosed area before he stopped work and left for lunch. He was re-entering the building upon his return when he collapsed and died. It was subsequently determined that Employee #1 died of carbon monoxide poisoning.

Keywords: VENTILATION, CONSTRUCTION, INHALATION, SAW, AIR CONTAMINATION, EXHAUST FUMES, POISONING, OVEREXPOSURE, CARBON MONOXIDE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Commercial building Alteration or rehabilitation $50,000 to $250,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 300494374 Fatality Asphyxia Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Cutting concrete pavement
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close