Accident Report Detail
Accident Summary Nr: 200651461 - Employee Is Burned by Hot Wax Blowoff
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 309840411 | 11/28/2007 | 2671 | 322221 | International Converter |
Abstract: At approximately 3:00 p.m. on November 27, 2007, Employee #1 was working in a paper converting operation. Employee #1 was applying heat to a wax piping system while the pump was running, using a blow torch to loosen congealed wax in elbow areas. The system had been shut down for a pump change out. Employee #1 was wearing safety goggles and gloves, but no other PPE. Lockout procedures had not been developed or used for this job. Employee #1 was hunched down over the assembly which was located under a tank platform. The hot wax pressurized and erupted through a replacement flange and washer assembly (the washer partially disintegrated). The system had been equipped with heat jacketing, but that had been removed during equipment modifications. Employee #1 sustained second-degree burns over his right arm and stomach area (15-percent of his body) when the pressurized hot wax sprayed out from a flanged pipe. At the time of the incident, another employee had stopped to talk to Employee #1 and he was able to assist Employee #1 immediately to a deluge shower which significantly reduced the level of injury. Employee #1's was hospitalized and his arm injury required skin grafting and extended follow-up because of secondary infections.
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation |
|---|---|---|---|---|---|---|
| 1 | 309840411 | Hospitalized injury | Burn/Scald(Heat) | Machine operators, not specified |