Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200651370 - Employee Is Pinned Between Beam and Lift, Later Dies

Accident Summary Nr: 200651370 -- Report ID: 0521100 -- Event Date: 10/19/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
12201821110/22/20073441332312Merrill Iron & Steel Inc

Abstract: At approximately 9:30 p.m. on October 19, 2007, Employee #1 was found pinned between a crane rail and the aerial lift man basket that he was riding in. Employee #1 was operating a Genie Model Number Z 45/25 aerial lift from the basket position. Employee #1 had been in Bay Number 4 hooking up electrical control panels. The vehicle was moved across the aisle to the north end of Bay Number 3. From that location Employee #1 raised the man basket up approximately 17 ft to the level of two crane rails. Employee #1 had his back to the rails while operating the controls and apparently looking in the direction of the center of the bay when he went high enough to contact the upper rail and got crushed between the rail and the control panel. There was no work for Employee #1 in that area. It is not known why Employee #1 was there. Employee #1 was observed by other employees in the area. Employee #1 was lowered down by an employee who knew how to operate the ground level controls. Employee #1 was hospitalized and died three days later.

Keywords: BEAM, PINNED, CRANE LIFTING BEAM, CRUSHED, AERIAL LIFT, CRANE, INATTENTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 122018211 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close