Accident Summary Nr: 200651073 - Employee Is Killed When Crushed by Crane

Accident Summary Nr: 200651073 -- Report ID: 0521100 -- Event Date: 08/02/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30680072308/02/20053321331511De Pere Foundry Inc

Abstract: At approximately 8:30 a.m. on August 2, 2005, Employee #1, a maintenance worker, was working with a coworker, a maintenance lead man, on a 5-ton auxiliary hoist of a 30-ton crane. The coworker was training Employee #1 on the maintenance procedures for this crane. The crane operator was below to warn adjacent cranes away from the work being performed, but was not watching the pendant, and was not told to do so. The lead man assumed the operator below would watch the pendant. The employer's written lock-out procedure for this crane calls for the entire rail to be deenergized and locked out, which was rarely done as there are 3 cranes operating on this rail. Typically, power is disconnected and locked-out at the crane itself. The power was left on in this instance because the hoist had to be operated to diagnose and adjust-fix the hoist problem. There was no acceptable procedure addressing how to accomplish this particular task. The general lock-out procedures call for a spotter. Another coworker below needed to move the crane and did so at the pendant. He did not know anyone was on top of the crane, and there were no warning signs or tags posted. He grabbed the pendant and began to move the crane. Several workers yelled to stop, and he immediately dropped the controls. The crane coasted a few feet to the point where Employee #1 and the coworker were pinned between the gearbox of the crane and the roof beam of the foundry. The coworker, being a smaller person, was able to work himself out from the pinching point without injury. Employee #1 was crushed and eventually died.

Keywords: MAINTENANCE, PINNED, WORK RULES, LOCKOUT, CRUSHED, CRANE, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 306800723 Fatality Bruise/Contus/Abras Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close