Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200643245 - Employee Dies in Gas Well Drilling Operation

Accident Summary Nr: 200643245 -- Report ID: 0627700 -- Event Date: 05/30/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30806385806/01/20051381213111Saber Drilling Company, Inc.

Abstract: At 1:45 p.m. on May 30, 2005, Employee #1 and Employee #2, working as part of a four-man crew, were drilling a new gas well. The drilling operations required the replacement of a lower spool when changing from 7-in. pipe to 4-in. pipe. A representative from another company delivered the replacement spool. At this time, the employees' supervisor left the work area and the representative directed the crew to remove the 18,000-lbs stack as one piece, in order to prevent disassembling the unit and to save time. The stack consisted of the spool to be replaced, a blowout preventer, upper spool and rotary head. Chains had been hooked to two of four attachments on the blowout preventer. The stack was lifted several times, and despite the lower spool being mostly unbolted, it was stuck to the blowout preventer. Employee #1 and Employee #2 were using pry bars to free the spool, when the top heavy stack fell over and struck both employees. Employee #1 was killed, and Employee #2 received multiple bruises but his injuries did not require hospitalization.

Keywords: CHEST, INADEQUATE MAINT, WORK RULES, WELL, NATURAL GAS, MANUAL MAT HANDLING, STRUCK BY, FALLING OBJECT, OIL RIG

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308063858 Fatality Other Occupation not reported
2 308063858 Non Hospitalized injury Bruise/Contus/Abras Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close