Accident Summary Nr: 200643005 - Storage tank containing sulfuric acid ruptures

Accident Summary Nr: 200643005 -- Report ID: 0627700 -- Event Date: 08/30/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30805908808/31/20043479332812Valmont Coatings-Oklahoma Galvanizing

Abstract: At approximately 9:08 a.m. on August 30, 2004, employees responded to an emergency situation. A storage tank containing 93 percent sulfuric acid ruptured and its contents were released to the environment. Employees responded to the acid spill by constructing a dike, using gravel, lime and sand. Forklift drivers removed galvanized poles from the spill. The acid reacted with the lime, and released a white "cloud" with irritating properties which enveloped many of the responding employees. The employer called the Claremore Fire Department HAZMAT Team who responded to the scene. When the HAZMAT Team arrived employees were ordered to cease activities. This facility used sulfuric acid in the galvanizing process. The horizontal tank that ruptured had a storage capacity of 3,770 gallons of sulfuric acid and was located outside the facility in containment. It was used to replenish the sulfuric acid dip tanks. It was not designed and manufactured as a pressure vessel. The tank ruptured during the transfer of acid from the storage tank to dip tank(s) located inside the plant. Acid was transferred from the storage tank to dip tank(s) by pressurizing the storage tank with compressed plant air. The compressed plant air line went through an in-line air dryer which had not been maintained according to the manufacturer's instructions. The compressed air pressure to the storage tank was normally reduced from 120 psig by a regulator down to 30 psig. However, engineering design criteria specified that the regulator be set at 10-15 psig. After the accident, the regulator was found to be set at 90 psig. In addition, the regulator had recently been replaced and did not meet the engineering design specifications of the original regulator. An accident investigation concluded that the tank ruptured due to over-pressurization within the tank. After their exposure, employees reported burning faces, throats, headaches, and chest pain. Many of the employees coughed and choked, and had difficulty in breathing. The Claremore Fire Department HAZMAT Team decontaminated 18 employees and sent them all to Claremore Regional Hospital where they were treated for their exposure. Fourteen employees were hospitalized overnight.

Keywords: BURN, THROAT, INHALATION, STORAGE TANK, RUPTURE, EXPLOSION, CHEMICAL REACTION, HIGH PRESSURE, SKIN, SULFURIC ACID

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308059088 Hospitalized injury Other Occupation not reported
2 308059088 Hospitalized injury Other Occupation not reported
3 308059088 Hospitalized injury Other Occupation not reported
4 308059088 Non Hospitalized injury Other Occupation not reported
5 308059088 Hospitalized injury Other Occupation not reported
6 308059088 Non Hospitalized injury Other Occupation not reported
7 308059088 Hospitalized injury Other Occupation not reported
8 308059088 Non Hospitalized injury Other Occupation not reported
9 308059088 Hospitalized injury Other Occupation not reported
10 308059088 Hospitalized injury Other Occupation not reported
11 308059088 Hospitalized injury Other Occupation not reported
12 308059088 Hospitalized injury Other Occupation not reported
13 308059088 Non Hospitalized injury Other Occupation not reported
14 308059088 Hospitalized injury Other Occupation not reported
15 308059088 Hospitalized injury Other Occupation not reported
16 308059088 Hospitalized injury Other Occupation not reported
17 308059088 Hospitalized injury Other Occupation not reported
18 308059088 Hospitalized injury Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close