Accident Summary Nr: 200642387 - Employee died due to burns from an explosion

Accident Summary Nr: 200642387 -- Report ID: 0627700 -- Event Date: 02/18/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30496152702/19/200233250American Foundry Group

Abstract: On February 18, 2002, Employee #1, a melter, was performing melting operations when a wet piece of metal was dropped into the induction furnace. The heat from the furnace vaporized the liquid from the metal, causing it to erupt from the furnace. The expansion of liquid discharged molten liquid upon Employee #1. The explosion of hot molten metal covered 90 percent of his body surface. He was transported to a local burn unit of a hospital where he died of pneumonia resulting from the burn suffered in the accident.

Keywords: BURN, EXPLOSION, MOLTEN METAL, MELTING FURNACE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 304961527 Fatality Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.