Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200640506 - Employee dies of carbon monoxide poisoning

Accident Summary Nr: 200640506 -- Report ID: 0627700 -- Event Date: 10/15/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
10886783910/17/199628730Terra Nitrogen Corporation

Abstract: Employee #1, an instrument and electrical maintenance operator, was found unconscious in the plant, with only faint signs of life. He was taken to a local hospital, where he died shortly after arrival. The medical examiner's report indicated that he had died of carbon monoxide poisoning.

Keywords: UNCONSCIOUSNESS, VAPOR, VENTILATION, INHALATION, CHEMICAL VAPOR, POISONING, OVEREXPOSURE, CARBON MONOXIDE, CHEMICAL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108867839 Fatality Asphyxia Machinery maintenance occupations

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.