Accident Summary Nr: 200640068 - Employees burned in fire while closing natural gas well

Accident Summary Nr: 200640068 -- Report ID: 0627700 -- Event Date: 04/03/1996
Inspection NrDate OpenedSICNAICSEstablishment Name
10887069204/12/199613110Graham-Michaelis Corporation

Abstract: At approximately 3:15 p.m. on April 3, 1996, Employees #1 through #3 went to a well that was to be abandoned to remove casing tubes and then to plug and cement the opening. The well had a history of high-pressure natural gas and had produced natural gas for many years. The casing pullers rigged up on the well on the day before the accident. They released the pressure from the well, which amounted to a relatively small amount of gas. They then tried to determine how much casing could be pulled from the well. The casing was shot at 4,570 ft, and an unsuccessful attempt was made to pull loose this amount of casing. The casing was shot again at 3,540 ft, but it still would not come loose. On the day of the accident, the work-over rig stretched the casing to figure out its free-point, which was determined to be about 2,200 ft. The casing was shot at 2,122 ft and 20 joints of casing were pulled from the well. The casing pullers were circulating mud in preparation for cementing the well when a pocket of hydrocarbons shot out of the well. The gaseous and liquid hydrocarbons were apparently ignited by the pump engine on the rear of the pump trailer. Employees #1 through #3 sustained burns, for which they were hospitalized.

Keywords: BURN, GAS WELL, FLAMMABLE LIQUID, FLAMMABLE VAPORS, FIRE, NATURAL GAS, HIGH PRESSURE, GAS WELL DRILLING, ACCIDENTAL DISCHARGE, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 108870692 Hospitalized injury Burn/Scald(Heat) Occupation not reported
2 108870692 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 108870692 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.