Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200631737 - Employee killed in fall from power plant walkway

Accident Summary Nr: 200631737 -- Report ID: 0316400 -- Event Date: 09/15/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
11652715109/15/20071629237990Pullman Power Llc

Abstract: On September 15, 2007, Employee #1 and coworkers were working in a newly constructed 600 ft tall stack at a power plant. The crew noticed that the lighting was dimmer than usual, and Employee #1 and a coworker were sent to an approximately 203 ft high metal walkway to see what the problem might be. They used a man-hoist and an aluminum pick to reach the walkway. Employee #1 separated from his coworker and was near the end of the walkway next to a ladder when the coworker heard a loud noise. Another coworker on a lower level shouted, "Man down!" Employee #1 was found on the concrete floor; he died of injuries sustained in the fall. Employee #1 was using fall protection and was apparently tied off to a horizontal lifeline while in the hoist, but it was unclear whether he tied off to another line on the walkway. The walkway had an opening for a material hoist. When Employee #1's body was found, both lanyards attached to the right D-ring.

Keywords: MAINTENANCE, WORK RULES, CONSTRUCTION, CATWALK, FALL, FALL PROTECTION, FLOOR OPENING, ELEVATED WORK PLAT, TIE-OFF
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Powerplant New project or new addition $20,000,000 and over 620 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 116527151 Fatality Other Boilermakers Distance of Fall: feet
Worker Height Above Ground/Floor: 203 feet
Cause: Installing equipment (HVAC and other)
Fatality Cause: Fall from/with structure (other than roof)

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.