Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200631141 - Employee Is Killed from Asphyxiation While Abrasive Blasting

Accident Summary Nr: 200631141 -- Report ID: 0316400 -- Event Date: 03/14/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30707218103/14/20053499332999U.E.I. Coating And Metal Division

Abstract: On March 14, 2005, Employee #1 was performing abrasive blasting in a blasting room, which contained a blasting hood. He was wearing a Clemco supplied air respirator that shared its supplied air with the hood. This supplied air was provided through an Ingersoll-Rand, portable air compressor, Model Number 185. Employee #1 had borrowed the compressor approximately 2 weeks before for the abrasive blasting operation, due to the compressor his company normally uses, for abrasive blasting and breathing air, was broken. Before beginning the abrasive blasting assigned for his work shift, Employee #1 gathered his equipment and checked the engine oil, oil cooling oil, and filled the gas tank of the compressor. About 1.5 hours into Employee #1's shift, he was scheduled for a break, but did not show up in the designated area. A coworker went to check on Employee #1 and discovered Employee #1 lying face down on the floor of the blasting room, and was unresponsive. Emergency services were contacted and coworkers performed CPR on Employee #1 until they were relieved by local emergency service personnel. Employee #1 was pronounced dead. The accident investigation revealed that the nozzle that controlled the supplied air flow had been turned off, due to a mechanical malfunction. Additionally, it was determined that Employee #1's company was using an air compressor that was not rated for breathing air and carbon monoxide was not being properly monitored in the blasting room.

Keywords: OXYGEN DEFICIENCY, ASPHYXIATED, COLLAPSE, ABRASIVE BLASTING, TOXIC ATMOSPHERE, INHALATION, GAS, AIR HOSE, CARBON MONOXIDE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307072181 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close