Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200630929 - Four employees are poisoned when exposed to chemicals

Accident Summary Nr: 200630929 -- Report ID: 0316400 -- Event Date: 07/10/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30548907207/14/20037699562998C&K Industrial Services
Inspection NrDate OpenedSICNAICSEstablishment Name
30548906407/11/20037699562998Norseman Environmental Inc.

Abstract: On July 10, 2003, Employees #1, #2, #3, and #4 were working inside a tanker car that was being removed from service. They were cleaning residual material from the sides of the car, which was used to transport fuel tar. Employee #1 became ill and reported it to his supervisor. Employee #1 described his symptoms as being blue, vomiting, and losing consciousness momentarily. Employee #1 was transported to Weirton Medical Center, treated for methemoglobinemia, and released the following day. Employees #2, #3, and #4 who were inside the tanker car with Employee #1 also reported feeling ill and were also sent to Weirton Medical Center. They were admitted, at least one employee was treated, and all were released the following morning. All employees were cleared to return to work after discharge. The material that the employees were cleaning from the inside of the tankers contained naphthylene, benzene, aniline, toluidines, pyridines, and other compounds. Aniline and naphthylene are known to cause the formation of methemoglobin. The employees were wearing full encapsulating suits with hoods, double gloves, which were chemical resistant, boots, and full facepiece, North respirators with organic vapor and acid mist cartridges. The investigation revealed that an initial assessment of the respiratory hazards inside the tanker had never been done. No assessment of benzene exposure was done. The employees had not been fit tested for the respirators they were wearing.

Keywords: TANK TRUCK, VAPOR, INHALATION, TANK CLEANING, FUEL TRUCK, POISONING, TANK, CHEMICAL, RESPIRATOR

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 305489072 Hospitalized injury Poisoning(Systemic) Laborers, except construction
2 305489072 Hospitalized injury Poisoning(Systemic) Laborers, except construction
3 305489072 Hospitalized injury Poisoning(Systemic) Laborers, except construction
4 305489064 Hospitalized injury Poisoning(Systemic) Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.