Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200624724 - Employee Is Killed When Struck by Falling Car Bed

Accident Summary Nr: 200624724 -- Report ID: 0454711 -- Event Date: 03/14/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31192867503/18/20087538811111Victor L Hernandez Dba Auto Servicio El Bronco

Abstract: On March 14, 2008, Employee #1, a 29-year-old manager and mechanic employed for approximately one year at an auto repair shop, was underneath the bed of a car carrier (tow truck) in the east parking lot of the auto repair shop. As Employee #1 was removing oil from the hydraulic system, the bed lowered onto his head, and he was killed.

Keywords: HEAD, HYDRAULIC FLUID, MECHANIC, LOCKOUT, STRUCK BY, TOW TRUCK, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311928675 Fatality Concussion Supervisors, mechanics and repairers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close