Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200622306 - Employee dies of burns received while welding

Accident Summary Nr: 200622306 -- Report ID: 0454715 -- Event Date: 02/05/2003
Inspection NrDate OpenedSICNAICSEstablishment Name
30612826502/05/20031796238290Jabezco Industrial Group Inc

Abstract: On February 5, 2003, Employee #1 was TIG welding on an open pipe when a combustible liquid (majeisol 47 oil) discharged from the pipe and covered his body. The oil was ignited by the welding operation and Employee #1 was killed of burns over approximately 95 percent of his body.

Keywords: BURN, WELDER, WELDING, COMBUSTIBLE LIQUID, PIPE
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Manufacturing plant Maintenance or repair $500,000 to $1,000,000 1 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 306128265 Fatality Burn/Scald(Heat) Welders and cutters Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause:
Fatality Cause: Fire/explosion

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.