Accident Summary Nr: 200613024 - Employee Fractures and Burns Hand in Thermo Press Machine

Accident Summary Nr: 200613024 -- Report ID: 0111700 -- Event Date: 06/30/2008
Inspection NrDate OpenedSICNAICSEstablishment Name
31158596206/30/20082671322221Hampshire Paper Corp.

Abstract: On June 30, 2008, an employee and coworker were operating a Thermo-Press machine equipped with two hand trips, manufactured by Allen-Bradley, Model 800Z-GL3 Series B. They were installed to match the Thermo-Press units. The company had put two-hand trips in place to improve safety. The trips needed to be activated within 0.3 seconds of each other. If only 1 was tripped or if both were not tripped within 0.3 sec of each other, the unit would not cycle. The two hand trips were not equipped with guards over the top of them, which may have assisted in preventing inadvertent operation. Allen-Bradley did manufacture guards for the trips, but Production Manager stated that they were not purchased because they thought that they were not needed. The employee was using Machine Number, when she apparently reached back toward the press head at the completion of a cycle to retrieve the finished part with her left hand. As she reached for a new sheet with the right hand, the unit cycled. The employee suffered severe fractures and burns to the left hand, according to the ambulance service. During the inspection, it was noted that when the metallic paper is dragged across the two hand trip sensor, it activated. It was possible for both trips to inadvertently activate within the 0.3 second timeframe, and the unit to cycle.

Keywords: BURN, FRACTURE, CAUGHT BETWEEN, POINT OF OPERATION, STRUCK BY, PRESS OPERATOR, HAND, PRESS

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 311585962 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close