Accident Summary Nr: 200612588 - Two Employees Are Injured in Explosion

Accident Summary Nr: 200612588 -- Report ID: 0111700 -- Event Date: 06/12/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
30955761906/13/20073562332991The Timken Company Dba Timken Aerospace

Abstract: On June 12, 2007, Employees #1 and #2 were installing a shim (test probe) into a heat furnace. This function requires two people, where one worker inserts the shim into the furnace, while the other worker simultaneously opens the door of the furnace, by means of a remote foot pedal, to prevent hot gases under pressure from jetting out of the shim port when the valve is opened for insertion of the shim. While Employee #1 had the furnace valve opened and was inserting the shim, Employee #2 depressed the foot pedal, which was located approximately 15 feet from the furnace. At this moment, an electrical cabinet next to the shim port blew out. Employee #1 was knocked backwards by the door of the cabinet and received a penetrating chest wound, and lacerations to his head, face, arms, and upper body from the flying debris. Employee #2 was blown back several feet as well from the explosion, suffering a few minor bruises. Employee #1 was taken to a nearby hospital, where he was hospitalized and underwent surgery. The incident investigation showed that a pump used to sample the gases in the furnace during heat treating had been placed in the electrical cabinet. The pump was rated only to pump air and to operate at temperatures below 104 degrees Fahrenheit, but the gases that were sampled from the furnace were normally several hundred degrees. The mixture also contained an organic chemical. The combination of high temperatures and the presence of the organic chemical were determined to be the route cause, resulting in failure of the pump seals and o-rings. This failure then allowed the gas mixture to seep into the cabinet, accumulate, and ignite when the relay to open the door of the furnace was tripped resulting in the explosion.

Keywords: CHEST, IGNITION SYSTEM, EQUIPMENT FAILURE, EXPLOSION, FALL, STRUCK BY, FLYING OBJECT, CONTUSION, PUNCTURE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309557619 Hospitalized injury Puncture Furnace, kiln and oven operators
2 309557619 Non Hospitalized injury Bruise/Contus/Abras Furnace, kiln and oven operators

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close