Accident Summary Nr: 200611176 - Contact with Overhead Line thru Boom

Accident Summary Nr: 200611176 -- Report ID: 0111700 -- Event Date: 06/19/2001
Inspection NrDate OpenedSICNAICSEstablishment Name
30254279006/19/200107830Lucas Tree Experts

Abstract: A tree trimmer was performing line-clearance tree-trimming work near a 12.47-kilovolt (phase-to-phase) overhead power line. He was working from an aerial lift. A ground worker was working about 45 meters away. The aerial lift truck was parked facing downhill alongside a road. The power line crossed the road approximately 6 meters from the downhill side of the truck. The tree trimmer had finished trimming branches on the side of the road with no power line. With the boom elevated above the power line, the tree trimmer swung the aerial lift bucket to trim branches away from the power line on the other side of the road. After he began trimming on that side of the road, he moved the bucket to another position. He lost sight of the power line, and the boom contacted the power line. The tree trimmer heard an arcing noise and felt the additional tension on the boom from the power line. He immediately moved the bucket to a higher location, away from the power line. No one was injured in the accident.

Keywords: OVERHEAD POWER LINE, ELECTRICAL, BOOM, E PTD, TREE, TREE TRIMMING, AERIAL LIFT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 302542790 Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close