Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200570927 - Window Washer Is Killed in Fall

Accident Summary Nr: 200570927 -- Report ID: 0316700 -- Event Date: 05/02/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30847221605/03/20057349561790Clearwater Services

Abstract: On May 2, 2005, Employee #1, the sole proprietor of Clearwater Services, was about to begin cleaning the windows of a three-story building, which was 49.5-ft high. He was using a main line consisting of a seatboard with a Rope Descent System (RDS) and a safety line comprised of a fall arrest harness, lanyard, rope grab and vertical lifeline. Apparently, Employee failed to connect his seatboard to the main line rope descent system before crawling over the parapet. He fell and was killed. He was found hanging 6 ft above ground level in his harness, asphyxiated by the chest strap. The safety lifeline was incorrectly sized for the rope grab and failed to properly restrain Employee #1's fall.

Keywords: CHEST, WINDOW WASHER, ASPHYXIATED, LIFELINE, CLEANING, LANYARD, FALL, FALL PROTECTION, NECK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 308472216 Fatality Asphyxia Supervisors, cleaning and building service workers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close