Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200570331 - ELECTRIC SHOCK - GROUND FAULT IN HEATING GUN

Accident Summary Nr: 200570331 -- Report ID: 0316700 -- Event Date: 05/10/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
11621256405/10/200030890Buckell Plastic Company, Incorporated

Abstract: An employee was performing maintenance on a large grounded piece of equipment. He was using a defective heating gun and extension cord. He was later found lying on the floor. He had apparently been electrocuted.

Keywords: ELECTRICAL, E GI VII, ELECTROCUTED, GROUND FAULT, EQUIPMENT GROUNDING, ELECTRIC CORD, ELEC EQUIPMENT--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 116212564 Fatality Electric Shock Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.