Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200556389 - Employee Is Overcome by Hydrogen Sulfide and Dies in Fall

Accident Summary Nr: 200556389 -- Report ID: 0625700 -- Event Date: 03/06/2011
Inspection NrDate OpenedSICNAICSEstablishment Name
31476960503/07/20111799238990Koch Specialty Plant Services, Inc.

Abstract: At approximately 3:00 p.m. on March 6, 2011, ten workers were performing maintenance on a 180-ft process tower. Employee #1 and a coworker were doing site preparation to install a 20-inch nozzle on the tower at the 100-ft level. Five of the ten workers were at the very top of the tower preparing to do confined space entry for internal tower work. Three workers were at the ground level doing structural work. The personal hydrogen sulfide (H2S) meters on Employee #1 and his coworker started to alarm at the same time. The coworker called out on his radio, alerting the other workers, including a ground level supervisor, of the encounter with the H2S. Immediately, all workers on the tower began to descend from their respective levels. Employee #1 and his coworker began descending from the 100-ft level and encountered an increasingly dangerous atmosphere. As those workers at the very top began to descend, their personal meters began alarming. The ground level superintendent suspected that the H2S was at a higher concentration near the 100-ft level and called out on the radio for those workers that were in the process of descending from the very top to go back up. Employee #1 and his coworker began to lose consciousness and fell from their respective locations. Employee #1 fell down to the deck near the 100-ft level. His coworker slid down the ladder cage that connected the deck near the 100-ft level to the deck below. The coworker slid down into a more breathable atmosphere, sustaining bruising but survived with minor injuries. Employee #1 passed out from the H2S gas and suffered blunt trauma to his head, resulting in his death.

Keywords: HEAD, UNCONSCIOUSNESS, HYDROGEN SULFIDE, ALARM, STRUCK AGAINST, INHALATION, LOCKOUT, FALL, CHEMICAL VAPOR, POISONING
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Refinery Maintenance or repair $50,000 to $250,000 10 180 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 314769605 Fatality Poisoning(Systemic) Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Erecting structural steel
Fatality Cause: Asphyxiation/inhalation of toxic vapor

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.