Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200554459 - Shipfitter Is Killed When Load Falls on Him

Accident Summary Nr: 200554459 -- Report ID: 0625700 -- Event Date: 07/10/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
30908744307/11/20063731336611Northrop Grumman Ship Systems

Abstract: At about 2:00 p.m. on July 10, 2006, Employee #1 and three coworkers (all shipfitters) were walking under a 125-ton suspended load (a navigation room for a ship) to meet a superintendent that was already there, surveying the equipment attached to the suspended load. While the five workers were under the load, one of the two slings supporting it failed. The tensile load exerted on the wire rope sling that failed exceeded the manufacturer's capacity. This caused one of the sides of the suspended load to fall to the ground, fatally striking Employee #1.

Keywords: FRACTURE, SHIPYARD, WIRE ROPE, OVERLOADED, SUSPENDED LOAD, EQUIPMENT FAILURE, SHIP, STRUCK BY, SLING, FALLING OBJECT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 309087443 Fatality Fracture Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.