Accident Summary Nr: 200553899 - Three Employees Are Burned in Explosion

Accident Summary Nr: 200553899 -- Report ID: 0625700 -- Event Date: 05/21/2005
Inspection NrDate OpenedSICNAICSEstablishment Name
30760252405/23/20051389213112Baker Energy

Abstract: At approximately 8:35 a.m. on May 21, 2005, three employees were welding a 4-inch pipe that was attached to a 1,000 lb ground storage tank. The tank was empty and had been pressure washed, but previously contained oil. As Employees #1, #2, and #3 were welding, an explosion occurred. All three employees were hospitalized and treated for second-and third-degree burns. The accident investigation revealed that although the storage tank was pressure washed, the piping connected to the storage tank had not been cleaned.

Keywords: BURN, FLAMMABLE LIQUID, FIRE, LUBRICATING FLUID, STORAGE TANK, WELDING, EXPLOSION, PIPE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307602524 Hospitalized injury Burn/Scald(Heat) Production helpers
2 307602524 Hospitalized injury Burn/Scald(Heat) Production helpers
3 307602524 Hospitalized injury Burn/Scald(Heat) Production helpers

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close