Accident Summary Nr: 200553659 - Employee Killed at Tow Site

Accident Summary Nr: 200553659 -- Report ID: 0625700 -- Event Date: 10/25/2004
Inspection NrDate OpenedSICNAICSEstablishment Name
30759740111/01/20043273327320Lee'S Ready Mix

Abstract: On October 25, 2004, Employee #2 attempted to pull Employee #1's ready mix truck, containing eight yards of concrete, out of the mud. Each employee hooked an end of a sling, with attached eye to his vehicle. Employee #2 attached an end of the sling to the tow hook attachment at the right rear of his vehicle. Employee #1 attached the other end of the sling to one of the two hookup points at the front of his truck. As Employee #2 moved his truck, Employee #1's truck also began to move, and without warning, the tow hook detached and was propelled through the cab windshield of Employee #1's truck, striking and killing Employee #1. The tow hook system had been installed by the employer, utilizing bolts of unknown grade, which may have exceeded their intended load capacity during the operation. .

Keywords: CONCRETE TRUCK, STUCK, STRUCK BY, CONCUSSION, FLYING OBJECT, SLING, CONCRETE, MUD PIT

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 307597401 Fatality Concussion Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close