Accident Report Detail
Accident Summary Nr: 200553196 - Employee killed in crane accident
| Inspection Nr | Date Opened | SIC | NAICS | Establishment Name |
|---|---|---|---|---|
| 305962391 | 12/23/2003 | 1622 | 237310 | F. Miller & Sons, Inc. |
Abstract: On December 22, 2003, Employee #1 and coworkers were unloading concrete pilings, weighing 53,000 lbs, from truck/trailers using a crane. While unloading the second piling, the crane tipped, causing the main pendant lines that were supporting the boom to fail. The boom fell to the ground and struck Employee #1 on the head. Employee #1 was pronounced dead.
| End Use | Project Type | Project Cost | Stories | Non-building Height | Fatality | ||
|---|---|---|---|---|---|---|---|
| Bridge | New project or new addition | $250,000 to $500,000 | X | ||||
| Employee # | Inspection Nr | Age | Sex | Degree of Injury | Nature of Injury | Occupation | Construction |
|---|---|---|---|---|---|---|---|
| 1 | 305962391 | Fatality | Fracture | Occupation not reported | Distance of Fall: feet Worker Height Above Ground/Floor: feet Cause: Pile driving Fatality Cause: Collapse of structure |
Translate