Accident Summary Nr: 200552370 - Three employees injured while pressure testing tank

Accident Summary Nr: 200552370 -- Report ID: 0625700 -- Event Date: 04/17/2002
Inspection NrDate OpenedSICNAICSEstablishment Name
30447562704/17/200237310T.T. Coatings, Inc.

Abstract: At approximately 3:15 p.m. on April 17, 2002, Employees #1 and #2 were modifying a vacuum tank that had been removed from a vacuum truck. The employees were pressure testing the vessel when some of the "dogs" holding the rear hatch in place broke. The rear hatch released and injured the two employees working on the vessel and Employee #3 who was walking by the vessel. All three employees were taken to area hospitals for treatment. The employer was modifying two vacuum tanks to be used in pressure service without any information relating to the design and construction of the tanks. At the time of the incident, the tank had been fitted with a pressure release valve (PRV) that would release at 125 psi. The yard pressure was approximately 60 psi and could vary from as low as 50 psi to as high as 75 psi since no regulators were installed on the pressure lines, except at the main storage tank. The maximum working pressure of the tank was 25 psi with a test pressure of 37.5 psi, which could only be hydro tested and not pressure tested. The employer was not aware of the tank's working pressure because no documentation was provided from the friend that gave the tanks to the employer nor did the employer request the information. The tanks had been de-certified by DOT.

Keywords: HATCH, VACUUM VESSEL, STRUCK BY, CONCUSSION, TANK, PRESSURE RELEASE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 304475627 Hospitalized injury Concussion Supervisors, mechanics and repairers
2 304475627 Hospitalized injury Concussion Plumbers, pipefitters and steamfitters
3 304475627 Hospitalized injury Concussion Welders and cutters

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.