Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200551687 - Employee crushed and killed by falling crane gantry

Accident Summary Nr: 200551687 -- Report ID: 0625700 -- Event Date: 12/14/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30308330712/14/200034790Bredero Price Company

Abstract: At approximately 11:30 a.m. on December 14, 2001, Employee #1 and coworkers were moving a Manitowoc 3900W crawler crane across a road. The power lines running along the road made it necessary to lower the gantry assembly onto the roof of the crane. The crane's boom had already been lowered onto a flatbed trailer truck and they intended to support the rear of the crane with a bucket loader. The truck developed a leak in its compressed air system that disabled its air brakes, so the mechanic/foreman went to a shop across the street and get what he needed to fix the truck. Since the job was delayed, the yard supervisor took one coworker to start him on different job. Shortly thereafter, Employee #1, the truck driver, and the crane operator decided to lower the gantry assembly. The crane operator entered the cab to work the controls, the driver stood on the right tread to act as a signalman, and Employee #1 went onto the roof of the crane to remove the pins holding the gantry's back hitches. The signalman was directed to boom down rapidly by Employee #1, but when excess slack developed in the cables, the gantry assembly achieved a snap-over-center configuration and slammed down onto the roof of the crane. The movement of the gantry assembly was so fast that Employee #1 was unable to get clear and he was crushed against one of the counterweights located on the crane's roof.

Keywords: WORK RULES, CRAWLER CRANE, GANTRY CRANE, CAUGHT BETWEEN, CRUSHED, MECH MAT HANDLING, FALLING OBJECT, CRANE

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303083307 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close