Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200551604 - Employee killed by flying dome of transport tanker

Accident Summary Nr: 200551604 -- Report ID: 0625700 -- Event Date: 10/31/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30308283811/02/200028190Industrial Maintenance Corporation

Abstract: At approximately 10:15 a.m. on October 31, 2000, Employee #1 and two coworkers, all maintenance employees, were hydrotesting and visually inspecting a truck trailer used to transport hydrogen fluoride. They successfully completed the hydrotesting portion of the work and were removing the dome on the top of the trailer's tank to inspect the interior. In some manner, the safety valve at the rear of the trailer lost air pressure and it tripped, shutting off the discharge for the tank. At about the same time, the manual valve on the top of the trailer was shut, closing off the input to the tank. This arrangement allowed some of the compressed air used to blow out the water from the hydrotesting to become trapped in the tank. Employee #1 was removing the bolts securing the dome to the trailer when the trapped, compressed air blew him and the dome off the trailer. He was struck on the head by the flying dome before landing on the concrete surface next to the tank. Employee #1 was killed.

Keywords: TANK TRUCK, AIR PRESSURE, HEAD, SAFETY RELIEF VALVE, COMPRESSED AIR, TANK CLEANING, STRUCK BY, FLYING OBJECT, MECH MALFUNCTION

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303082838 Fatality Cut/Laceration Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close