Accident Summary Nr: 200551166 - One employee killed, three injured in oil well gas explosion

Accident Summary Nr: 200551166 -- Report ID: 0625700 -- Event Date: 01/18/2000
Inspection NrDate OpenedSICNAICSEstablishment Name
30307882801/20/200013890Tiger Well Service, Inc.

Abstract: Employee #1 and coworkers were running a completion string in an oil well and needed to pull the work string and run a different isolation packer on the production string of pipe. When they arrived to work, they found pressure at 350 psi on the well casing and 50 psi on the tubing. They decided to bleed the pressure off to the open mud tank close to the rig. They relieved the gas cap off the well head until they got oil back to the surface. They then pumped filtered brine back into the well to kill it so they could come out of the hole and run the production tubing and packer. While they were pumping the brine into the well and taking returns to the open mud pit, a natural gas cloud formed, which was ignited by an unknown source and exploded. Employees #1 through #4 sustained burns and were transported to the hospital. Employee #1 later died; Employees #2 through #4 were released after approximately two weeks for treatment on an outpatient basis. The source of ignition was most likely a gasoline engine on the trash pump that was pumping the brine through the filtration system.

Keywords: BURN, VAPOR, FIRE, NATURAL GAS, GAS, EXPLOSION, OIL WELL SERVICING, SPARK

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 303078828 Fatality Burn/Scald(Heat) Occupation not reported
2 303078828 Hospitalized injury Burn/Scald(Heat) Occupation not reported
3 303078828 Hospitalized injury Burn/Scald(Heat) Occupation not reported
4 303078828 Hospitalized injury Burn/Scald(Heat) Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.