Accident Summary Nr: 200550689 - Employee killed when struck by falling pallet and material

Accident Summary Nr: 200550689 -- Report ID: 0625700 -- Event Date: 06/08/1999
Inspection NrDate OpenedSICNAICSEstablishment Name
30199522106/09/199917710Ceco Concrete Construction, Llc.

Abstract: At approximately 2:00 p.m. on June 8, 1999, Employee #1, the concrete manager for Ceco Concrete Construction, and a coworker were on the fifth level of the LSU Life Sciences building, which was under construction. The general contractor was using a Manitowoc crawler crane, model 888, to unload galvanized metal parts from a truck and place them in storage on the ground level adjacent to the crane. This required the loads be palletized. The pallets were rigged by employees of the general contractor and supported by two 2 in. wide nylon slings secured to the crane hook. As one load was passing over the fifth floor, the pallets tilted and the load spilled onto the work area. Employee #1 was struck in the back and on the neck by some of the falling metal parts. He suffered fractures and internal injuries, and was killed. There was no signalman on the fifth level communicating with the crane operator so that workers could be alerted when a load was passing over them. The load involved in the accident was not well secured to the pallets, most of which were shrink-wrapped. An industrial truck, such as a Lull High-Reach, might have been a better choice for this task, but there was no such machine on site.

Keywords: FRACTURE, PALLETIZED CARGO, UNSECURED, WORK RULES, CRAWLER CRANE, CONSTRUCTION, BACK, OFF LOADING, STRUCK BY, FALLING OBJECT
Accident Details
End Use Project Type Project Cost Stories Non-building Height Fatality
Other building New project or new addition $1,000,000 to $5,000,000 6 X

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation Construction
1 301995221 Fatality Fracture Occupation not reported Distance of Fall: feet
Worker Height Above Ground/Floor: feet
Cause: Forming
Fatality Cause: Struck by falling object/projectile

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close