Accident Summary Nr: 200541571 - Employee Is Caught in Steel-Forming Machine and Asphyxiated

Accident Summary Nr: 200541571 -- Report ID: 0317500 -- Event Date: 03/13/2007
Inspection NrDate OpenedSICNAICSEstablishment Name
31029056403/14/20073317331210Ipsco Koppel Tubulars Corporation

Abstract: On March 13, 2007, Employee #1 was working for a firm that produced steel pipe and tubes from purchased steel. He was working with some components on a caster at the facility. Specifically, he was removing the motor and straightener stand from one of the strands of the caster. The system had been locked out in the main control room, but there was, stored in a cylinder, residual energy that had not been released. A hydraulic fluid flushing valve was activated, causing the head of the straightener to pivot and crush Employee #1 between a motor and the frame of the straightener. The cause of death was asphyxia.

Keywords: CHEST, ASPHYXIATED, CASTER, STEEL, CYLINDER, PRESSURE VESSEL, STEEL TUBE, LOCKOUT, CAUGHT BETWEEN, CRUSHED

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310290564 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close