Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200541472 - Employee Is Killed in Fall from Aerial Lift

Accident Summary Nr: 200541472 -- Report ID: 0317500 -- Event Date: 10/04/2006
Inspection NrDate OpenedSICNAICSEstablishment Name
31028732110/06/20063544333514Penn United Technology Inc.

Abstract: On October 4, 2006, Employee #1 was working from an aerial lift, removing a conduit and wiring. The lift was loaded in such a way that the center of gravity was offset, causing it to tip over. The employee fell about 12 ft and was killed as a result.

Keywords: CONDUIT, ELECTRIC CABLE, OVERLOADED, ELECTRICAL WORK, LOCKOUT, FALL, UNTRAINED, AERIAL LIFT, OVERTURN, WARNING SIGN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 310287321 Fatality Fracture Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.