Powered by GoogleTranslate

Occupational Safety and Health Administration OSHA

Accident Report Detail

Accident: 200540615 - One Employee Killed, Four Injured By Steam

Accident: 200540615 -- Report ID: 0317500 -- Event Date: 02/05/2001
InspectionOpen DateSICEstablishment Name
30281863802/06/20011799Patent Construction System

Five employees of a scaffolding company were building a scaffold inside the combustion chamber of a fluidized bed boiler. The boiler had been shut down due to a tube leak. Residual ash was left in the particle return system. The employees were testing in order to locate the leak when water entered the particle return system and came in contact with the hot ash. This caused an eruption of steam and ash. Employee #1 sustained burns on 90 percent of his body and died. Employee #2 sustained second- and third-degree burns on 80 percent of his body. Employee #3 sustained second- and third-degree burns on 60 percent of his body. Employee #4 sustained burns on 30 percent of his body. Employees #2, 3 and 4 were hospitalized. Employee #5 was not hospitalized.

Keywords: burn, abdomen, ash, boiler, steam, high temperature
Accident Details
End Use Proj Type Proj Cost Stories NonBldgHt Fatality
Powerplant Maintenance or repair Under $50,000 5 45 X

Employee Details
Employee # Inspection Age Sex Degree Nature Occupation
1 302818638 Fatality Burn/Scald(Heat) Construction trades, n.e.c.
2 302818638 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c.
3 302818638 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c.
4 302818638 Non Hospitalized injury Other Construction trades, n.e.c.
5 302818638 Hospitalized injury Burn/Scald(Heat) Construction trades, n.e.c.

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.