Powered by GoogleTranslate

Accident Report Detail

Accident Summary Nr: 200535615 - Two Employee Are Killed after Carbon Monoxide Overexposure

Accident Summary Nr: 200535615 -- Report ID: 0751910 -- Event Date: 03/14/2013
Inspection NrDate OpenedSICNAICSEstablishment Name
31701971903/15/20132048311119Schneider Milling Inc.

Abstract: At approximately 12:30 p.m. on March 14, 2013, Employee #1 and Employee #2, with Schneider Milling Inc., entered into a 72 ft diameter grain bin to unclog the auger. Employee #1 had radio contact with a coworker outside the bin. Employee #1 had asked the coworker for a tape measure and a rod to unclog the hole. The coworker turned on the auger to remove about 5 bushels of corn to clear the auger hole on the South side of the bin, so the coworker could hand the tools through the auger opening to Employee #1. The coworker then went to shut off the truck near-by, so that the coworker could hear Employee #1 easier over the radio. When the coworker attempted to make contact with Employee #1, about 1 to 2 minutes later, there was no response. The coworker then climbed to the top of the grain bin to see what was going on. The coworker noticed Employee #1 and Employee #2 slumped over on top of the grain. The coworker radioed another coworker, who called 911. Employee #1 and Employee #2 were retrieved through a hole cut on South side of the grain bin by a rescue crew. Employee #1 and Employee #2 were taken by ambulance to the Hospital, where they were pronounced dead. It was determined the following day that there was a fire smoldering under the grain inside the bin, and that the Carbon Monoxide levels reached as high as 600 ppm.

Keywords: ASPHYXIATED, AUGER MECHANISM, FIRE, TOXIC ATMOSPHERE, TRUCK, NOISE, CARBON MONOXIDE, COMMUNICATION, GRAIN BIN

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 317019719 Fatality Asphyxia Occupation not reported
2 317019719 Fatality Asphyxia Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close