Accident Summary Nr: 200535193 - Worker Is Crushed in Cereal Factory

Accident Summary Nr: 200535193 -- Report ID: 0751910 -- Event Date: 07/18/2012
Inspection NrDate OpenedSICNAICSEstablishment Name
31662950007/19/20127361561310Randstad Us, Lp

Abstract: On July 17, 2012, Employee #1 was working as a contract laborer working for the contract employer Ranstad US, LP. He had been assigned to work at a General Mills, Inc., facility in Cedar Rapids, Iowa. Randstad provided contract labor for the cereal packaging area. Employee #1 was the lead worker for the second shift. General Mills was testing a new box material using line 3A in cereal packaging. Stickers were normally placed on "cubes," which were pallet-size shrink-wrapped boxes at a fixed location designated for the activity. Stickers or labels notified the shipping department not to ship the test materials. Employee #1 had just started working. The narrative did not further distinguish that comment by noting whether Employee #1 had just commenced his shift or his assignment at General Mills. He noticed one cube that was not labeled. The unlabeled cube had bypassed the labeling station. Employee #1 moved down the line to place the sticker on the cube. The package was situated on a "T-car." T-cars, or transfer cars, transported material inside the facility. The T-car went into motion, creating a pinch point that crushed Employee #1. He was crushed between a stationary barrier pole and a 4-inch by 4-inch (102-millimeter by 102-millimeter) steel beam on a T-car. The stationary barrier pole was made of concrete. It was 6.5 inches (165 millimeters) in diameter and 49.25 inches (1.25 meters) tall. Employee #1 was killed.

Keywords: CHEST, FRACTURE, LOCKOUT, CAUGHT BETWEEN, CRUSHED, CONVEYOR, ELDERLY, MECH MAT HANDLING, PALLET, MACHINE--MISC

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 316629500 Fatality Fracture Laborers, except construction

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.

Close