Accident Summary Nr: 200533339 - Employee Is Killed When Grinding Wheel Shatters

Accident Summary Nr: 200533339 -- Report ID: 0751910 -- Event Date: 02/17/2010
Inspection NrDate OpenedSICNAICSEstablishment Name
31422528502/18/20103714336312Eaton Corporation

Abstract: On February 17, 2010, Employee #1 was working for a manufacturer of gasoline engines and engine parts. He was operating a Landis grinder, when the wheel on the grinder shattered, causing the guard on the grinding wheel to break apart. A large fragment of the grinding wheel struck Employee #1 in the right side of his face. Employee #1 was pronounced dead at the scene.

Keywords: HEAD, MACHINE OPERATOR, ENGINE, EQUIPMENT FAILURE, STRUCK BY, FLYING OBJECT, FACE, GRINDING WHEEL

Employee Details
Employee # Inspection Nr Age Sex Degree of Injury Nature of Injury Occupation
1 314225285 Fatality Other Occupation not reported

Thank You for Visiting Our Website

You are exiting the Department of Labor's Web server.

The Department of Labor does not endorse, takes no responsibility for, and exercises no control over the linked organization or its views, or contents, nor does it vouch for the accuracy or accessibility of the information contained on the destination server. The Department of Labor also cannot authorize the use of copyrighted materials contained in linked Web sites. Users must request such authorization from the sponsor of the linked Web site. Thank you for visiting our site. Please click the button below to continue.